PublicationDetail

Chair for Computer Aided Medical Procedures & Augmented Reality
Lehrstuhl für Informatikanwendungen in der Medizin & Augmented Reality

THIS WEBPAGE IS DEPRECATED - please visit our new website

B. Wiestler, C. Baur, P. Eichinger, , T. Zhang, V. Biberacher, C. Zimmer, , J. Kirschke, S. Albarqouni
Fully Automated Multiple Sclerosis lesion detection on multi-channel subtraction images through an integrated Computer Vision- Machine Learning pipeline
Clinical Neuroradiolgy (2017) 27:S1-S118 (bib)

Background
MR imaging is a mainstay of MS disease activity as- sessment. However, lesion detection is time-consuming and subject to relevant inter-observer variability. We have therefore aimed to develop an integrated analysis pipeline for automatic detection and segmenta- tion of new or enlarged MS lesions in subtraction images over time. Methods: Initially, a multi-step computer vision pipeline marks can- didate lesions on both DIR & T1 subtraction images, using constraints on shape and intensity. Next, shape, intensity and neighborhood fea- tures were extracted from each lesion, and an oblique random forest (RF) classifier was trained on a set of segmented subtraction maps of 42 patients. Classification accuracy was validated in 22 previously un- seen patients. Results: In the validation cohort, the computer vision pipeline marked 866 candidate lesions. Of these, 207 were true lesions, while 8 true le- sions were missed, mostly because of their small size (detection rate 96.2%). The RF classifier for separating noise from true lesions reached a total accuracy of 95.3% (Fig. 1A), detecting 192 of 207 marked lesions (92.7%, Fig. 1B). Intriguingly, the algorithm also identified nine MS lesions which have previously been overlooked by two neuroradiologists. The software therefore correctly labelled 192/215 new lesions (detection rate 89.3%). Conclusions: A Computer Vision-Machine Learning pipeline rely- ing on shape, intensity and neighborhood features can detect new or enlarged MS lesions with a compelling detection rate of 89%, which is well within the range of human readers in contemporary trials. Intriguingly, the pipeline even detected previously overlooked MS lesions, highlighting the potential of computer-assisted radiology.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.



Edit | Attach | Refresh | Diffs | More | Revision r1.13 - 30 Jan 2019 - 15:16 - LeslieCasas

Lehrstuhl für Computer Aided Medical Procedures & Augmented Reality    rss.gif