PublicationDetail

Chair for Computer Aided Medical Procedures & Augmented Reality
Lehrstuhl für Informatikanwendungen in der Medizin & Augmented Reality

THIS WEBPAGE IS DEPRECATED - please visit our new website

G. Zahnd, A. Karanasos, G. van Soest, E. Regar, W. Niessen, F. Gijsen, T. van Walsum
Semi-automated Quantification of Fibrous Cap Thickness in Intracoronary Optical Coherence Tomography
International Conference on Information Processing in Computer-Assisted Interventions (bib)

Acute coronary syndrome represents a leading cause of death. Events are triggered by rupture of atheromatic plaques, as a result of disruption of the overlying fibrous cap. Pathological studies have shown that cap thickness is a critical component of plaque stability. Therefore, assessment of fibrous cap thickness could be a valuable tool for estimating the risk of future events. To aid preoperative planning and peri-operative decision making, intracoronary optical coherence tomography imaging can provide very detailed information about arterial wall structure. However, manual interpretation of the images is laborious, subject to variability, and therefore not always sufficiently reliable for immediate decision of treatment. We present a novel semi-automatic computerized interventional imaging tool to quantify coronary fibrous cap thickness in optical coherence tomography. The most challenging issue when estimating cap thickness is caused by the diffuse nature of the anatomical abluminal interface to be detected. Our method can successfully extract the fibrous cap contours using a robust dynamic programming framework based on a geometrical a priori. Validated on a dataset of 90 images from 11 patients, our method provided a good agreement for minimum cap thickness with the reference tracings performed by a medical expert (35.7 ± 33.3 µm, R=.68) and was similar to inter-observer reproducibility (35.2 ± 33.1 µm, R=.66), while being significantly faster and fully reproducible. This tool demonstrated promising performances and could potentially be used for online identification of high risk-plaques.
This material is presented to ensure timely dissemination of scholarly and technical work. Copyright and all rights therein are retained by authors or by other copyright holders. All persons copying this information are expected to adhere to the terms and constraints invoked by each authors copyright. In most cases, these works may not be reposted without the explicit permission of the copyright holder.



Edit | Attach | Refresh | Diffs | More | Revision r1.13 - 30 Jan 2019 - 15:16 - LeslieCasas

Lehrstuhl für Computer Aided Medical Procedures & Augmented Reality    rss.gif